Electrical Characteristics

Absolute Maximum Ratings for the Module

 

Stress exceeding maximum ratings even for short time may damage the module. Functional operation above the recommended operating conditions is not guaranteed. Extended exposure to stress above the recommended operating conditions may affect device reliability.

 

Table 2: Absolute Maximum Ratings

Parameter

Symbol

Rating

Unit

Supply voltage

VCCmax

-0.2 to +3.6

V

I/O voltage

VI / VO

-0.3 to +3.6

V

Storage temperature

TS

-40 to +85

°C

 

Table 3: Operating Conditions for the Module

Parameter

Symbol

Min.

Typ.

Max.

Unit

Power supply

VCC

3.15

3.3

3.45

V

Power consumption

(at 3.3V)

P

 

1.3

2.0

W

Ambient temperature

Ta

-40

 

+70

°C

 

Table 4: Operating conditions for application interface

Parameter

Symbol

Min.

Typ.

Max.

Unit

Input voltage high

VIH

2.0

 

 + 0.3

V

Input voltage low

VIL

-0.3

 

0.8

V

Output voltage high

VOH

 -0.1

 

 

V

Output voltage low

VOL

 

 

0.1

V

 

All further specifications and timings assume the application of the above mentioned operating conditions.