Comment: Edited DC Bridges and Image.

...

The UART-interface of the Renesas Synergy S7G2-SK is accessable through the J10 connector. Please set jumper J9 to 3-5 and 4-6 (RS485 mode). Then the UART TX line from the Synergy CPU will be connected to Pin 4 of J10. This is where the RX line from the USB-Serial converter needs to be connected. You can access the UART by launching a serial monitor like putty. Choose the following settings:

Speed

115200

Data Bits

8

Stop Bits

1

Parity

None

Flow Control

XON/XOFF

Application

After setting up the serial monitor and starting the application, the output should look like this:

...