Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Parameter

Symbol

Rating

Unit

Supply voltage

VCCmax

-0.2 to +3.6

V

I/O voltage

VI / VO

-0.3 to +3.6

V

Storage temperature

TS

-40 to +85

°C

 

Table 3: Operating Conditions for the Module

Parameter

Symbol

Min.

Typ.

Max.

Unit

Power supply

VCC

3.15

3.3

3.45

V

Power consumption

(at 3.3V)

P

 

1.3

2.0

W

Ambient temperature

Ta

-40

 

-40 to +70

°C

 

Table 4: Operating conditions for application interface

Parameter

Symbol

Min.

Typ.

Max.

Unit

Input voltage high

VIH

2.0

 

 + 0.3

V

Input voltage low

VIL

-0.3

 

0.8

V

Output voltage high

VOH

 -0.1

 

 

V

Output voltage low

VOL

 

 

0.1

V

 

All further specifications and timings assume the application of the above mentioned operating conditions.

...