Absolute Maximum Ratings for the Module
Stress exceeding maximum ratings even for short time may damage the module. Functional operation above the recommended operating conditions is not guaranteed. Extended exposure to stress above the recommended operating conditions may affect device reliability.
Table 2: Absolute Maximum Ratings
Parameter | Symbol | Rating | Unit |
Supply voltage | VCCmax | -0.2 to +3.6 | V |
I/O voltage | VI / VO | -0.3 to +3.6 | V |
Storage temperature | TS | -40 to +85 | °C |
Table 3: Operating Conditions for the Module
Parameter | Symbol | Min. | Typ. | Max. | Unit |
Power supply | VCC | 3.15 | 3.3 | 3.45 | V |
Power consumption (at 3.3V) | P |
| 1.3 | 2.0 | W |
Ambient temperature | Ta | -40 |
| +70 | °C |
Table 4: Operating conditions for application interface
Parameter | Symbol | Min. | Typ. | Max. | Unit |
Input voltage high | VIH | 2.0 |
| + 0.3 | V |
Input voltage low | VIL | -0.3 |
| 0.8 | V |
Output voltage high | VOH | -0.1 |
|
| V |
Output voltage low | VOL |
|
| 0.1 | V |
All further specifications and timings assume the application of the above mentioned operating conditions.