  • Configurable number of modules and slots

  • Up to 73 byte of process data* per direction when Datamapper is chosen

    • input data, output data, ioxs, status information (optional generic data provider, optional apdu status)

    • direction of output data is limited to 69 byte when optional generic data provider is used

    • up to 1 ms cycle time

  • Up to 1434 byte of process data per direction when RPC transport is chosen

    • cycle time must not be less then 100ms

  • Support for process alarms

  • Support for record data (read, write), where a maximum of 1116 byte can be accessed in each direction

  • Support for Redundancy (MRP) (FW Rev. 2.1)

  • Dynamic module configuration (provided by connection request from PLC) for modules mapped to the cyclic channel (FW Rev. 2.1)

Info

*IOXS will take one byte additionally to each mapped submodule