Parameter | Symbol | Rating | Unit |
Supply voltage | VCCmax | -0.2 to +3.6 | V |
I/O voltage | VI / VO | -0.3 to +3.6 | V |
Storage temperature | TS | -40 to +85 | °C |
Table 3: Operating Conditions for the Module
Parameter | Symbol | Min. | Typ. | Max. | Unit |
Power supply | VCC | 3.15 | 3.3 | 3.45 | V |
Power consumption (at 3.3V) | P |
| 1.3 | 2.0 | W |
Ambient temperature | Ta | -40 |
| +70 | °C |
Table 4: Operating conditions for application interface
Parameter | Symbol | Min. | Typ. | Max. | Unit |
Input voltage high | VIH | 2.0 |
| + 0.3 | V |
Input voltage low | VIL | -0.3 |
| 0.8 | V |
Output voltage high | VOH | -0.1 |
|
| V |
Output voltage low | VOL |
|
| 0.1 | V |
All further specifications and timings assume the application of the above mentioned operating conditions.
...