Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Absolute Maximum Ratings for the Module

 

Stress exceeding maximum ratings even for short time may damage the module. Functional operation above the recommended operating conditions is not guaranteed. Extended exposure to stress above the recommended operating conditions may affect device reliability.

 

Table 2: Absolute Maximum Ratings

Parameter

Symbol

Rating

Unit

Supply voltage

-0.2 to +3.6

V

I/O voltage

-0.3 to +3.6

V

Storage temperature

-40 to +85

°C

 

Table 3: Operating Conditions for the Module

Parameter

Symbol

Min.

Typ.

Max.

Unit

Power supply

3.15

3.3

3.45

V

Power consumption

(at 3.3V)

 

1.3

2.0

W

Ambient temperature

-40

 

-40 to +70

°C

 

Table 4: Operating conditions for application interface

Parameter

Symbol

Min.

Typ.

Max.

Unit

Input voltage high

2.0

 

 + 0.3

V

Input voltage low

-0.3

 

0.8

V

Output voltage high

 -0.1

 

 

V

Output voltage low

 

 

0.1

V

 

All further specifications and timings assume the application of the above mentioned operating conditions.