  • PROFINET stack, Conformance Class B, Real Time Class 1

  • EtherNet/IP stack

  • EtherCAT stack

  • Web server

  • TCP channels (maximum throughput of 32kBit/s)

  • UDP channels (maximum throughput of 32kBit/s)

  • cyclic communication channel for real time data (PROFINET process data, EtherNet/IP process data) with at least 64 byes input/output data and up to 73 byte input and 73 byte output data (depending on the protocol stack) and a cycle time of 1 ms

  • RPC interface for management, application setup and non realtime data

...

  • EtherCAT

  • Dynamic PDO assignment and dynamic PDO mapping

  • SDO Info service

  • SDO service

What functionality is not supported

  • Exceeding process data over the cyclic channel (64 byte) by using RPC service

Frame specification

...